ASTM B117-07A PDF

The salt spray (or salt fog) test is a standardized and popular corrosion test method, used to ASTM B was the first internationally recognized salt spray standard, originally published in Other important relevant standards are. Designation: B – 07a Standard Practice for Operating Salt Spray (Fog) Apparatus1 This standard is issued under the?xed designation B. ASTM B Testing, also known as a Standard Practice for Operating Salt ASTM B Testing requires controls over many operational parameters such as: .

Author: Dukus Vudoran
Country: El Salvador
Language: English (Spanish)
Genre: Video
Published (Last): 14 August 2008
Pages: 495
PDF File Size: 20.77 Mb
ePub File Size: 7.52 Mb
ISBN: 973-3-98723-642-9
Downloads: 49969
Price: Free* [*Free Regsitration Required]
Uploader: Zolobar

All other water will be referred to as reagent grade. It is generally desirable to control the temperature of the surroundings of the salt spray chamber and to maintain it as stable as possible. Position of Specimens During Exposure 7.

No, VLM has own development and production facilities for corrosion testing equipment. Vent piping should be of sufficient size so that a b17-07a of back pressure exists and should be installed so that no solution is trapped.

See Table 1 for a listing of these impurity restrictions. Salt Spray Test Chambers. Place the panels in the proximity of the condensate collectors. The fallout rate should be measured for 16 hours and it must range from 1. Such tests are commonly referred to as modified salt b117-077a tests. Individual reprints single or multiple copies of this standard may be obtained by contacting ASTM at the above address or at phonefaxor service astm.

Suspension from glass hooks or waxed string may be used as long as the speci? This formula yields a result aetm 53 g 1.

Salt spray test – Wikipedia

1b17-07a conditions of making the scratch shall be as de? The first climate cycle comprises a continuous indirect spray of neutral pH 6.

Preparation of Test Specimens 6. Walk-in chambers are usually constructed with a sloping ceiling. ISO standards by standard number. This is followed by 1.

Once a year the corrosivity of the salt spray test chamber has to be checked. Failure to meet this requirement implies instability in the chemical process of the pre-treatment, or the paint quality, which must be addressed immediately, so that the upcoming batches are of the desired quality.

  LETTERS BY JRD TATA PDF

Salt spray testing is popular because it is relatively inexpensive, quick, well standardized, and reasonably repeatable.

The first prerequisite for your test chamber to operate properly is that it is regularly serviced and well maintained. This spray is set to fall-out on to the specimens at a rate of 1.

SAL 3000-FL

This standard is subject to revision at any time by the responsible technical committee and must v117-07a reviewed every? Is VLM only a distributor of corrosion test chambers? Other test solutions have other chemicals added including acetic acid often abbreviated to ASS and acetic acid with copper chloride often abbreviated to CASS each one chosen for the evaluation of decorative b117-0a, such as electroplated copper-nickel-chromium, electroplated copper-nickel or anodized aluminum.

Nozzles calibrated for air consumption and solution-atomized are available.

Options for corrosion chambers. Nozzles may be located at the ceiling, or 0.

NOTE 1—Should it be desirable to cut test specimens from parts or from preplated, painted, or otherwise coated steel sheet, the cut edges shall be protected by coating them with paint, wax, tape, or other effective media so that the development of a galvanic effect between such edges and the adjacent plated or otherwise coated metal surfaces, is prevented.

Salt spray testing is an accelerated corrosion test that produces a corrosive attack to coated samples in order to evaluate mostly comparatively the suitability of the coating for use as a protective finish. ASTM G85 annex A1 — Acetic Acid Salt Spray Test non-cyclic This test can be used to determine the relative resistance to corrosion of decorative chromium plating on steel and zinc based die casting when exposed to an acetic acid salt spray climate at an elevated temperature.

Synthetic seawater solutions are also commonly specified by some companies and standards. These acidified test solutions generally have a pH of 3. This does not apply to running tap water. In this connection it is well to point out that Practice B is not applicable to the study or testing of decorative chromium plate nickel-chromium on steel or on zinc-base die castings or of cadmium plate on steel.

This test can be used to test the relative resistance to corrosion of aluminium alloys when exposed to a changing climate of acetic acid salt spray, followed by air drying, followed by high humidity, all at an elevated temperature. Otherwise cleaned air may be introduced into the bottom of a tower? This test can be used to test the relative resistance to corrosion paints on steelwhen exposed to a changing climate of dilute salt spray at ambient temperature, followed by air drying at and elevated temperature.

  INFORMATION TECHNOLOGY PROJECT MANAGEMENT JACK T.MARCHEWKA 4TH EDITION PDF

Bare metal shall not be used. Operations shall be so scheduled that these interruptions are held to a minimum. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, are entirely their own responsibility. The salt spray test has little application in predicting how materials or surface coatings will resist corrosion in the real-world, because it does not create, replicate or accelerate real-world corrosive conditions.

Results are represented generally as testing hours in NSS without appearance of corrosion products e. The level of the water must be maintained automatically to ensure adequate humidi?

Salt spray test

After cleaning, weigh each panel on an analytical balance to the nearest 1. Different coatings have different behavior in salt spray test and consequently, test duration will differ from one type of coating to another. For this purpose Test Method B and Practice G 85 are available, which are also considered by some to be superior for comparison of chemically treated aluminum chromated, phosphated, or anodizedalthough?

Table 2 shows the temperature, at different pressures, that are commonly used to offset the cooling effect of expansion to atmospheric pressure.

How can I check whether my salt spray test chamber operates properly? An 11 to 19 L 3 to 5-gal reservoir is required within the chamber, with the level controlled. Unit for filtering compressed air. How can I check whether my salt spray test chamber asmt properly? Your comments will receive careful consideration at a meeting of the responsible technical committee, which you may attend.

Please find more details at www. This page was last edited on 29 Octoberat